Nevco Engineers Pvt. Ltd.

Leak Detectors

Ultraprobe 2000

The industry’s most comprehensive analog ultrasound instrument!
Fast, accurate, and designed for ease of use, it often takes no more than 15 minutes to become competent in ultrasonic testing using the Ultraprobe® 2000

Find compressed air and faulty steamtraps, prevent machinery failure & listen to electrical systems for discharges.

  • Easy to use
  • Frequency adjust possibility 20-100 kHz
  • Accurate analogue meter with meter mode function
  • Ideally for point & shoot trouble shooting

The Ultraprobe® 2000 also enables data reporting through three modes: through auditory channels (via a headset that has been specifically selected for heavy duty industrial use), through a uniquely designed bi-modal analog meter, and through the ability to interface with vibration analyzers, & sound recording devices via the heterodyned output.

The Ultraprobe® 2000 can be adapted to test practically any problem in operating equipment with such features as:
  • FREQUENCY TUNING enables a user to tune into problem “sounds” while minimizing background interference
  • METER MODE selection adjusts the meter response from a real time response to an averaging response. This feature allows accurate adjustments for leak detection and for mechanical analysis.
Construction: Hand-held metered pistol type made with aluminum and ABS plastic
Circuitry: Solid State heterodyne receiver with temperature compensation
Frequency Response: Frequency Detect ultrasonic frequencies between 20 kHz and 100 kHz, continuously variable Frequencies are converted to 50 kHz to 3 kHz audio
Probes: Scanning Module patented Trisonic plug-in type consisting of a phrased array of multiple transducers for airborne ultrasound. This probe is shielded against RF interference.
Rubber Focusing Probe (flexible) slips over scanning module to concentrate conical directivity and to shield reception of stray ultrasound. Also fits over Stethoscope Module to shield against high ambient ultrasound while unit isat maximum sensitivity.
Stethoscope Module – Plug-in type, insulated probe with RF shielding; 11,4 cm (4 1/2′) long stainless steel probe tip, conically shaped for uniform surface contact. Stethoscope Extension Kit: 3-piece, segmented metal rods to increase stethoscope contact range for 50,8 cm (20”) and 76.2 cm (31”).
Transmitter: Patented warble tone transmission
Headset: Noise isolating type: Double headset wired monophonic. Impedance 16 ohms. Over 23 dB os noise attenuation. Meets or exceeds ANSI specifications and OSHA standards. For hard hat use.
Indicators: Ballastic output meter; linear calibration scale of 0-100 for logging relative measurements.
Meter is accurate 1% throughout entire scale. Low Level Battery LED indicator for main housing internal power supply.
Battery: Self contained NiMH rechargeable. RECHARGING SYSTEM: Standard 110V. Also availible in 220V.
Features: Frequency Tuning Adjustment Dial: 20-100 kHz with “fixed band” position for ultra-narrow frequency response.
Bi-Modal Meter Switch for logarithmic and linear meter scale adjustments.
Optional Auxiliary Mode selection for chart recorder output: 0-50 mV.
Sensitivity Control – Precision 10-turn adjustment dial with numerically calibrated sensitivity increments for finite gain adjustment.
Spring loaded trigger switch
Overall Size: Complete kit in Zero Halliburton aluminum carrying case:
47 x 37 x 17 cm (18.5 x 14.5 6.5 )
Pistol unit: 0.9 kg (2 lbs.)
Complete carrying case:6.4 kg (14 lbs.)
Sensitivity: Detecs 0.127 mm (0.005) diameter leak @ 0.34 bar (5 psi)
at a distance of 15.24 m (50ft.)
Threshold: 1 x 10-2 std. cc/sec to 1 x 10-3 std. cc/sec
Warranty: 1-year parts/labor standard.
5 years with completed warranty registration card.
Display Modes Logaritmic and linear * depends on leak configuration ** specify Ex rating if needed at time of order