CEMS Supplier in Kochi
CEMS Supplier in Kochi (Cochin): Continuous Emission Monitoring Systems
Kerala asks more of a CEMS than most states. Under the Kerala State Pollution Control Board’s online monitoring framework, an analyser must carry type approval, report digitally to the Board’s central server, raise an alarm when anyone changes its configuration or calibration, and pass a validation test against manual sampling before its data counts. For the refinery at Ambalamugal and the fertilizer, chlor-alkali and chemical units of Eloor-Edayar, a CEMS supplier in Kochi has to meet that checklist, not just deliver a working analyser.
Nevco Engineers has 44 years in environmental instrumentation, dating from 1982. We supply four stack gas analysers, System 400, AR650, AR602Z and LD500, and select them against both the gases in your consent and the Board’s requirements.
In short: In Kerala, a CEMS must be type-approved, connected, tamper-alerting and validated against manual sampling. Nevco helps Kochi plants choose an analyser that fits the gases and the rules, connects it to Kerala PCB and CPCB, and supports remote calibration and AMC.
Talk to our CEMS team: +91-9999946668 | sales@nevcoengineers.com | Request a Quote
Who Kerala PCB's Online Monitoring Covers
Units in CPCB’s 17 highly polluting categories, along with common biomedical and hazardous waste incinerators, were already required to monitor continuously. The Kerala PCB framework, summarised by Lexplosion in March 2022, extended coverage as a first step to:
- Red category industries with capital investment of ₹10 crore or more
- Orange category industries with capital investment of ₹15 crore or more
- Steel process industries, whatever their investment
- Hospitals with more than 500 inpatient beds
- Apartment and commercial projects that need Environmental Clearance
- Sewage and effluent treatment plants of 100 KLD or more
Deadlines were phased: 31 August 2022 for the 17 categories and units already instructed, 31 December 2022 for other red category units, and 30 June 2023 for other orange category units. A covered unit in Kochi should therefore already be reporting, and any new or expanded unit has to connect from the start.
For hospitals, housing projects and treatment plants, the requirement is mostly about effluent, which Nevco covers through effluent and STP monitoring. Stack gas monitoring matters most for the industrial units.
Kerala's CEMS Checklist, and How We Meet It
| Kerala PCB requirement | What it means in practice | How Nevco responds |
|---|---|---|
| Direct, continuous 24×7 measurement | The analyser reads pollutant concentration itself, around the clock | All four analysers measure continuously; the LD500 measures in situ with no sample extraction |
| Type approval from the Indian scheme or USEPA, TÜV or MCERTS, verified on the certifier’s website | Paperwork matters as much as performance | The AR650’s page lists a TÜV test report to EN 15267 (QAL1), MCERTS and CSIR-NPL verification; for other analysers we confirm documents before quoting |
| Installed to CPCB norms using a CPCB-approved principle | Measurement method and installation must follow CPCB | Stack survey and installation planned to CPCB requirements |
| Digital communication to a remote computer | Data must flow automatically to the Board’s server | NEVCO NV-LX logger built to the CPCB communication protocol, over Ethernet or 4G |
| Remote calibration supported | The Board accepts calibration run remotely | Nevco has delivered System 400 analysers with a remote calibration facility |
| Alarm on any configuration or calibration change | Tampering, or an unlogged change, is flagged | Configured during server integration; confirm the Board’s current format with us |
| Validation against manual sampling within CPCB accuracy | Data counts only after it matches lab results | We plan commissioning so the analyser is calibrated before the Board’s validation visit |
| Low operation and maintenance, low consumables | Running cost is a stated criterion | Cross-stack and in-situ designs avoid sample conditioning systems |
Kochi's Stacks by Zone
Eloor-Edayar along the Periyar
Fertilizer, chlor-alkali, sulphuric acid, rare earth and chemical units have shared this stretch of the Periyar for decades, beside dense housing. Stacks here carry SO₂, NH₃, HCl, Cl₂ and HF, often in wet, corrosive gas.
- AR602Z UV spectrometer-based gas monitoring system for stacks where HCl, Cl₂, NH₃, SO₂ and HF share a duct, read together without cross-interference
- LD500 in-situ gas analyzer for ammonia and HCl, which stick to sample lines
- System 400 for SO₂ on acid plant and boiler stacks
Ambalamugal refinery and petrochemical zone
BPCL’s Kochi Refinery at Ambalamugal lists benzene, toluene and propylene among its specialty products, and petrochemical units have grown around it. Process stacks and fired heaters carry SO₂, NOx, CO, and hydrocarbons.
- AR650 multi-component analyser for long gas lists, with benzene, toluene, xylene and total hydrocarbons among its parameters, and the certifications Kerala looks for
- System 400 in its 400CS or 400BASIC configuration for heaters and boilers
Our Global Partners














Nevco’s clients include Reliance, Tata Power, Indian Oil, HP, ONGC, GAIL, NTPC, BHEL, Adani, Essar, Hindalco, Vedanta, Jindal, NALCO, SAIL, IFFCO, UltraTech, ACC, Aditya Birla Group, Aarti Industries, Hikal, SRF, Dr. Reddy’s, Hindustan Unilever, Saint-Gobain, Maruti, Toyota, Honda, MRF, Goodyear and Wipro.
Pollution control authorities rely on Nevco too: CPCB, DPCC, TNPCB, PPCB, the MP Pollution Control Board and the Goa State Pollution Control Board are among our clients as well.
Kakkanad and the port area
IT parks, the special economic zone, the shipyard, the LNG terminal, and container berths have fewer process stacks. Boilers and captive power units are the usual CEMS candidates, and their KSPCB consent decides. Many units here fall under the framework for effluent rather than stack gases.
Nevco Work Relevant to Kochi
Nevco’s projects do not yet include a stack installation in Kerala. These are the closest matches:
- Sulphuric acid plant. Gas-phase SO₂ measurement across a 0 to 20% range, matching acid production in the Eloor-Edayar belt.
- Tata Steel Long Products, Joda. Three System 400 online SO₂ analysers with a remote calibration facility, the capability Kerala’s framework allows.
- Petcoke calciner and carbon plant. System 400 measuring SO₂, NOx and NH₃ in corrosive gas with more than 40% moisture.
- GAIL, Gandhar. Optical CEMS by UV-DOAS for waste incineration.
- SRF and Birla Corporation. Stack monitoring of SO₂, NOx and particulates.
In Kochi’s main sectors, Nevco’s client list includes refining and gas companies Indian Oil, HP, Reliance, ONGC, GAIL and Oil India, and fertilizer makers IFFCO and SPIC.
The company is certified to ISO 9001:2015 and ISO/IEC 27001:2013, holds a Best MSME Award, and works with principals including OPSIS, Sintrol and KANE. More than 10,000 of its flue gas analysers are installed across India.
Wet Stacks, Wet Seasons
Kochi gets rain from both the southwest and northeast monsoons, and many of its stacks leave wet scrubbers. Moisture condenses in sample lines and carries acid with it. The LD500 avoids sample lines entirely, and System 400 has run on gas with more than 40% moisture. On System 400 and AR650, the analyser links to the stack optics by fibre, so it can sit in a dry shelter away from the platform.
Stack gases are only one duty. Particulates need stack dust monitoring, and boundary air needs a continuous ambient air quality monitoring system. Data from all of them can reach Kerala PCB and CPCB through our IoT-CPCB connectivity.
How a Kochi CEMS Project Runs
- Consent and coverage check. We confirm whether your unit falls under the framework and which stacks and gases apply.
- Analyser and documents. We match analysers to the gases and confirm the type-approval papers Kerala PCB will ask for.
- Installation and integration. We install, calibrate and connect the system to Kerala PCB and CPCB servers.
- Validation support. We prepare the system for the Board’s comparison with manual sampling.
- AMC. Calibration, servicing and breakdown support continue under contract.
Request a CEMS Proposal for Your Kochi Plant
- Send your Kerala PCB consent and a list of stacks.
- We recommend analysers and list the certificates that come with them.
- You receive an itemised quote for equipment, installation, server connectivity, validation support and AMC.
- +91-9999946668
- sales@nevcoengineers.com
We are open from Monday to Saturday 10:00 AM - 06:00 PM
Frequently Asked Questions.
Have questions about our systems, compliance requirements, or service offerings? We’ve answered the most common ones here.
What is Kerala PCB's online emission monitoring system?
It is the Kerala State Pollution Control Board’s framework for online continuous effluent and emission monitoring. Covered units must install analysers that report continuously to a central server, with alerts, remote calibration and validation against manual sampling.
Which Kochi units must install online emission monitoring?
The 17 highly polluting categories, waste incinerators, red category units investing ₹10 crore or more, orange category units investing ₹15 crore or more, and all steel process industries. Large hospitals, EC projects and big STPs are covered too, mainly for effluent.
Does Kerala PCB accept any CEMS analyser?
No. The analyser needs type approval from the Indian scheme or from agencies such as USEPA, TÜV or MCERTS, and the certificate must be verifiable on the certifier’s website.
Which Nevco CEMS analyser lists TÜV and MCERTS certification?
The AR650. Its page lists a TÜV test report to EN 15267 (QAL1), MCERTS and CSIR-NPL verification. For other analysers, Nevco confirms the available documents before quoting.
How does Kerala PCB validate a new CEMS?
After installation, the Board compares manual sampling and analysis with the analyser’s real-time values. If they fall within CPCB’s prescribed accuracy, the system passes. If not, it must be recalibrated.
Does Kerala allow remote calibration of a CEMS?
Yes. The framework supports remote calibration, and the analyser must alert the central server whenever calibration or configuration changes. Nevco has delivered System 400 analysers with remote calibration.
Which gases should an Eloor-Edayar stack CEMS measure?
Typically SO₂, NH₃, HCl, Cl₂ and HF, depending on the process and consent. The AR602Z measures all of these together, and the LD500 suits sticky ammonia and HCl.
Which CEMS suits refinery stacks at Ambalamugal?
The AR650 for process stacks with long gas lists, including benzene, toluene, and total hydrocarbons, and System 400 for heaters and boilers measuring SO₂, NOx, and CO.
Which parts of Kochi do you cover?
We take on CEMS projects in Eloor, Edayar, Ambalamugal, Kakkanad, the Cochin port area and other industrial zones around Kochi, with AMC support after commissioning.
How do I get a CEMS quote in Kochi?
Send your Kerala PCB consent, the stacks and gases to be monitored, and site power and network details. We quote for analysers, installation, connectivity, validation support, and AMC.