Nevco Engineers Pvt. Ltd. 90 A, 2nd Floor, Opposite Iskon Temple, Amritpuri, B Main Road, East Of Kailash, Delhi - 110065
Hot Line: +91-9999946668

CEMS Supplier in Visakhapatnam


CEMS Supplier in Visakhapatnam (Vizag): Continuous Emission Monitoring Systems

Winter 2026-27 is a test for Visakhapatnam’s industry. After poor air in December 2025, the Andhra Pradesh Pollution Control Board (APPCB) inspected, issued notices, set deadlines and, in October 2026, fined industries ₹16.32 crore. Its chairman put the approach plainly: effective monitoring of industrial emissions and strict enforcement are essential. For steel, power, refinery, fertilizer and pharma units in the Visakhapatnam Bowl, a CEMS supplier in Visakhapatnam has to deliver stack data that holds up when the board comes back to check.

Nevco Engineers has been in environmental instrumentation for 44 years, since 1982. We supply four stack gas analysers, System 400, AR650, AR602Z and LD500, and match them to each process area APPCB is watching.

In short: APPCB has named the process areas it expects Vizag industries to control before winter. Nevco maps each one to the right analyser, connects it to APPCB and CPCB, and keeps it calibrated under an AMC, so the stack record speaks for itself.

Talk to our CEMS team: +91-9999946668 | sales@nevcoengineers.com | Request a Quote

How APPCB Tightened Its Grip in 2026

WhenWhat happened
December 2025Pollution levels rose in Visakhapatnam, prompting closer monitoring of industrial emissions
January 2026Task force inspections found compliance deficiencies, and notices were issued for corrective action
25 August 2026APPCB reviewed major industries of the Visakhapatnam Bowl area and set short-term and long-term measures to be in place before winter, as reported by Deccan Chronicle
October 2026APPCB fined violating industries a total of ₹16.32 crore, according to Deccan Chronicle

The August review named the areas of concern: the port, Pedagantyada, Gajuwaka, Lankapalem and Parawada. Directions covered emissions from coke oven batteries, captive power plants and sinter plants, dust from coal and ash handling, gypsum storage at a fertilizer plant, and odour from the pharma city. The board warned that non-compliance would bring stringent action.

Beyond these local measures, APPCB sets stack conditions in each unit’s Consent for Operation (CFO), and units in CPCB’s 17 highly polluting categories must send online data to CPCB under its online monitoring FAQ.

What APPCB's Directions Mean at the Stack

Process area APPCB namedGases usually in the CFONevco analyser
Coke oven batteriesSO₂, NOx, CO, H₂SSystem 400, which lists all four
Sinter plantsSO₂, NOx, COSystem 400 (400BASIC covers SO₂, NO, NO₂ and CO)
Captive and utility power plantsSO₂, NOx, CO, CO₂, mercury where requiredSystem 400, with the 400HWE configuration calibrated for total mercury
Refinery heaters and process stacksSO₂, NOx, CO, hydrocarbons, benzeneAR650 for the long gas list; System 400 for heaters
Fertilizer process stacksNH₃, SO₂, HFLD500 for ammonia and HF; System 400 for SO₂
Pharma process stacks and odour sourcesNH₃, HCl, H₂S, solvent vapoursAR602Z for mixed acid gases; AR650 for solvents

Two of APPCB’s concerns, ash drifting from ponds and dust from coal and ash transport, are fugitive sources that no stack analyser can measure. Those need boundary monitoring by a continuous ambient air quality monitoring system, and stack particulates need stack dust monitoring. We say this up front so you invest in the right system for each problem.

The Four Analysers in One Line Each

System 400 (OPSIS)

A turnkey non-contact CEMS covering SO₂, NO, NO₂, CO, CO₂, H₂O, HCl, total mercury, NH₃, HF, H₂S and TRS, with configurations from basic combustion to mercury.

AR650 (OPSIS)

FTIR-DOAS across the stack for about 20 compounds, including benzene, toluene and total hydrocarbons, with TÜV (EN 15267, QAL1), MCERTS and CSIR-NPL credentials listed on its page.

AR602Z

UV DOAS that reads NO, NO₂, SO₂, Cl₂, H₂S, NH₃, HCl, HF, and benzene together without cross-interference.

LD500

Laser measurement across the duct with no sample extraction, reading NH₃, HCl, HF, H₂S, CO, O₂, and CH₄ in hot, dusty gas.

Odour Is Measured Gas by Gas

APPCB asked the pharma city to strengthen odour control. A CEMS cannot measure “odour” as such, but it can measure the gases behind it. System 400 lists H₂S and total reduced sulphur (TRS), while the AR602Z and LD500 both list H₂S and NH₃. Continuous readings of these gases show whether odour controls are working and give unit evidence when complaints arise.

Our Global Partners

Nevco’s clients include Reliance, Tata Power, Indian Oil, HP, ONGC, GAIL, NTPC, BHEL, Adani, Essar, Hindalco, Vedanta, Jindal, NALCO, SAIL, IFFCO, UltraTech, ACC, Aditya Birla Group, Aarti Industries, Hikal, SRF, Dr. Reddy’s, Hindustan Unilever, Saint-Gobain, Maruti, Toyota, Honda, MRF, Goodyear and Wipro.

Pollution control authorities rely on Nevco too: CPCB, DPCC, TNPCB, PPCB, the MP Pollution Control Board and the Goa State Pollution Control Board are among our clients as well.

Nevco Work on India's East Coast and Beyond

There is no Visakhapatnam stack job on Nevco’s projects list yet. What carries over to Vizag’s plants:

  • NALCO, Angul, Odisha. Environmental monitoring on the boiler stacks of a 1,200 MW captive power plant (10 × 120 MW), relevant to Vizag’s coal-fired power units.
  • Tata Steel Long Products, Joda, Odisha. Three System 400 online SO₂ analysers with a remote calibration facility, in the steel sector.
  • Petcoke calciner and carbon plant. A wet, corrosive duty (moisture above 40%) where System 400 tracks SO₂, NOx and NH₃, much like coastal process stacks.
  • GAIL, Gandhar. An incinerator stack monitored by UV-DOAS optical CEMS, a close parallel for Parawada and Atchutapuram units that burn process waste.
  • Sulphuric acid plant. High-range SO₂ (0 to 20%) measured in the gas phase, useful where fertilizer units run acid plants.

Companies with operations in the region appear on Nevco’s client list, including HP, NTPC, Andhra Petrochemicals and Dr. Reddy’s. Steel and metals clients include SAIL, Jindal and Essar.

On credentials: ISO 9001:2015 and ISO/IEC 27001:2013 certification, a Best MSME Award, partnerships with OPSIS, Sintrol and KANE, and an installed base of over 10,000 flue gas analysers across India.

Data APPCB Can Rely On

Each analyser reports through the NEVCO NV-LX logger, which follows the CPCB communication protocol, and our IoT-CPCB connectivity sends readings to APPCB and CPCB over Ethernet or 4G. Our engineers integrate the servers themselves.

Coastal air adds salt and humidity to the shelter, and many Vizag stacks are wet. The LD500 has no sample line for moisture to collect in. On System 400 and AR650, fibre optics link the stack to an analyser housed in a protected shelter.

How We Take On a Vizag CEMS Project

  1. Review the CFO and APPCB directions. We list each stack and gas you must report.
  2. Survey. We check ports, platforms, power and network at each stack.
  3. Install and connect. Matched analysers are commissioned and linked to APPCB and CPCB.
  4. Maintain. An AMC covers calibration, servicing and breakdowns through the year.

Request a CEMS Proposal Before Winter

  1. Send your APPCB CFO, any recent directions and the stack list.
  2. We map each stack to an analyser and flag anything that needs ambient or dust monitoring instead.
  3. You get a costed proposal split into analysers, installation, APPCB connectivity and AMC.

We are open from Monday to Saturday 10:00 AM - 06:00 PM

Frequently Asked Questions.

Have questions about our systems, compliance requirements, or service offerings? We’ve answered the most common ones here.

Why is APPCB tightening action on Visakhapatnam industries?

Pollution rose in December 2025. Task force inspections in January 2026 found compliance gaps, a review in August set pre-winter deadlines, and in October 2026 APPCB fined violating industries ₹16.32 crore.

Nevco brings 44 years of Control emissions from coke oven batteries, captive power plants and sinter plants, stop ash and coal dust, store gypsum properly and strengthen odour control in the pharma city, all before winter.

Commonly SO₂, NOx and CO, with H₂S at coke ovens where the CFO requires it. Nevco’s System 400 lists all four gases.

System 400, which covers SO₂, NOx, CO and CO₂ and offers a 400HWE configuration for mercury. Nevco has monitored boiler stacks at NALCO’s 1,200 MW captive power plant in Angul.

It measures the gases behind the odour rather than odour itself. System 400 lists H₂S and TRS, and the AR602Z and LD500 list H₂S and NH₃.

The AR650 for process stacks with long gas lists, including benzene, toluene and hydrocarbons, and System 400 for fired heaters measuring SO₂, NOx and CO.

No. Ash ponds and coal transport are fugitive sources outside the stack. They need ambient air quality monitoring at the boundary, while stack particulates need a stack dust monitor.

APPCB regulates them through each unit’s Consent for Establishment and Consent for Operation. For the 17 highly polluting categories, readings also stream online to CPCB.

We take on CEMS projects in the steel plant zone, Gajuwaka, Pedagantyada, Lankapalem, Parawada, Atchutapuram, the Simhadri belt and the port area, with AMC support.

Share your APPCB CFO and any recent directions, plus a list of stacks, their gases and the power and network on site. Pricing follows stack count, analyser choice, installation and AMC term.