CEMS Supplier in Angul
CEMS Supplier in Angul: Continuous Emission Monitoring Systems
Angul-Talcher packs thermal power, an aluminium smelter, steel, ferro alloys, coal mines and washeries into one industrial belt, and Odisha has watched its stacks online for more than a decade. For the plants that operate here, a CEMS supplier in Angul has to handle gases that most cities never see in a stack, such as hydrogen fluoride from smelting, alongside the SO₂ and NOx of some of the largest coal-fired boilers in eastern India.
Nevco Engineers has 44 years in environmental instrumentation, since 1982, and has already worked in Angul: we carried out boiler stack monitoring for NALCO’s 1,200 MW captive power plant. For stack gases, our options are System 400, AR650, AR602Z and LD500, and in a belt this varied, every one of them has a job.
In short: Angul’s stacks range from huge coal-fired boilers to smelter fume treatment outlets carrying fluoride. Nevco, already proven in Angul, selects the analyser for each stack, connects it to OSPCB and CPCB, and maintains it under an AMC.
Talk to our CEMS team: +91-9999946668 | sales@nevcoengineers.com | Request a Quote
Every Angul Stack, Matched
| Stack | Gases usually in the consent | Nevco analyser |
|---|---|---|
| Utility and captive power boilers | SO₂, NOx, CO, CO₂, mercury where required | System 400, with the 400HWE configuration for total mercury |
| Smelter fume treatment plant outlets | HF, SO₂ | LD500 or AR602Z |
| Carbon and anode plant stacks | SO₂, NOx, HF | System 400 or AR602Z |
| Steel plant stacks, including coke ovens and sinter | SO₂, NOx, CO, H₂S | System 400 |
| Sponge iron kilns and ferroalloy furnaces | CO, SO₂ | System 400 (400BASIC) |
| Coal mines and washeries | No process stack | Dust control and ambient monitoring instead |
Particulates from all these stacks are measured by stack dust monitoring instruments. Mines, washeries, ash ponds and haul roads release fugitive dust that no stack analyser can see, which is a job for a continuous ambient air quality monitoring system.
Proven in Angul and Across Odisha
From Nevco’s projects:
NALCO captive power plant, Angul.
Environmental monitoring of the boiler stacks of a 1,200 MW plant made up of ten 120 MW units. Our team knows the site conditions here first-hand
Tata Steel Long Products, Joda, Odisha.
SO₂ measured by System 400 on three stacks, with a remote calibration facility, in Odisha's steel and sponge iron sector.
Petcoke calciner and carbon plant.
System 400 on wet, corrosive gas, close to a smelter's carbon area.
Birla Corporation
Stack monitoring of particulates, SOx and NOx.
Nevco’s client list includes NALCO, NTPC and Jindal, three of the largest operators in the Angul-Talcher belt, along with aluminium producers Vedanta and Hindalco and steelmaker SAIL.
Credentials behind the work: ISO 9001:2015 and ISO/IEC 27001:2013, a Best MSME Award, technology from OPSIS, Sintrol and KANE, and over 10,000 flue gas analysers supplied in India. Among the stack analysers, the AR650 carries the named credentials (TÜV EN 15267 QAL1, MCERTS, CSIR-NPL).
Our Global Partners














Nevco’s clients include Reliance, Tata Power, Indian Oil, HP, ONGC, GAIL, NTPC, BHEL, Adani, Essar, Hindalco, Vedanta, Jindal, NALCO, SAIL, IFFCO, UltraTech, ACC, Aditya Birla Group, Aarti Industries, Hikal, SRF, Dr. Reddy’s, Hindustan Unilever, Saint-Gobain, Maruti, Toyota, Honda, MRF, Goodyear and Wipro.
Pollution control authorities rely on Nevco too: CPCB, DPCC, TNPCB, PPCB, the MP Pollution Control Board and the Goa State Pollution Control Board are among our clients as well.
Data to OSPCB and CPCB
Stack readings reach OSPCB and CPCB through a NEVCO NV-LX logger running the CPCB communication protocol, over Ethernet or 4G, using our IoT-CPCB connectivity. The server integration stays with our own engineers. Where a plant runs many stacks, as most in Angul do, a common logger and data format keeps reporting consistent across units.
How We Take On an Angul CEMS Project
- Consent and EC review. We list every stack and gas in your OSPCB consent and Environmental Clearance.
- Survey. We inspect ports, platforms, power and network at each stack, with HF and wet outlets flagged early.
- Install and connect. Matched analysers are commissioned and linked to OSPCB and CPCB.
- Stay compliant. One AMC handles calibration, routine service and breakdowns for every unit on site.
Get a CEMS Proposal for Your Angul Plant
- We recommend an analyser for each stack, including HF and mercury where needed.
- You get a stack-by-stack price for analysers, installation, server connectivity and the AMC.
- Send your OSPCB consent and EC conditions with the list of stacks.
- +91-9999946668
- sales@nevcoengineers.com
We are open from Monday to Saturday 10:00 AM - 06:00 PM
Frequently Asked Questions.
Have questions about our systems, compliance requirements, or service offerings? We’ve answered the most common ones here.
How many online stack monitors run in Angul-Talcher?
OSPCB’s March 2016 status report counted 57 online stack monitors across nine industries in the aluminium, iron and steel and thermal power sectors, plus 29 real-time ambient stations.
Which stack gases does OSPCB expect industries to report?
OSPCB’s 2013 online monitoring scheme named PM, SO₂, NO₂ and HF for stacks. Each unit’s consent sets the exact list, which can also include CO, mercury and other gases.
Which CEMS measures HF at a smelter's fume treatment plant outlet?
The LD500 measures HF across the duct with no sample line, which suits a reactive gas. The AR602Z reads HF together with SO₂ and NOx where several gases must be reported.
Has Nevco worked in Angul?
Yes. Nevco carried out environmental monitoring of the boiler stacks at NALCO’s 1,200 MW captive power plant in Angul, which has ten 120 MW units.
Which CEMS suits Angul's coal-fired power plants?
System 400 handles the combustion gases, SO₂, NOx, CO and CO₂, and its hot-wet-extractive 400HWE version adds total mercury for boilers whose consent asks for it.
Do coal mines and washeries in Talcher need a CEMS?
Usually not, since they have no process stacks. Their emissions are dust from mining, crushing and transport, which is controlled at source and measured by ambient air quality monitoring.
Which CEMS suits ferro alloy furnaces and sponge iron kilns?
System 400 in its 400BASIC configuration, covering SO₂, NO, NO₂ and CO. Furnace and kiln particulates are measured separately by stack dust monitors.
Why is HF hard to measure with extractive CEMS?
HF is reactive and adheres to surfaces, so some of it can be lost in a sample line before analysis. In-situ measurement, as with the LD500, avoids that loss.
Which areas around Angul do you cover?
We take on CEMS projects in Angul, Talcher, Kaniha, Banarpal and nearby industrial areas of Odisha, with AMC support after commissioning.
How do I get a CEMS quote in Angul?
Share the OSPCB consent, EC conditions and a stack list with gases, plus what power and network are available. The price is built per stack from analyser, installation and AMC.